Matters needing attention for wiring harness maintenance of medical instruments and equipment

Date: 2021-03-30 Visited: 462

At present, the maintenance of medical equipment is a very complicated work, many medical institutions have equipment department, responsible for maintaining the safety and stability of equipment, but there are many problems that many equipment maintenance personnel do not understand or pay attention to. Here to everyone under the medical equipment wiring harness maintenance and maintenance.


The first point: meticulous daily maintenance, to ensure the normal operation of equipment is crucial.


Daily maintenance seems simple, but many times is not paid attention to, but also easy to ignore; But a lot of times big problems are compounded by small problems. To do with the clinical use of active cooperation, keep the surface of the instrument clean; Check whether the voltage and power supply are normal before use; During use, observe whether the function of the instrument is normal and fill in the use record. Develop good habits during routine maintenance to avoid damage.


Second point: equipment maintenance work, must be carefully handled, do not careless.


In case of equipment failure, information collection and preparation work should be done before maintenance. Including the model number, factory number, time of fault occurrence, abnormal sound when the fault occurs, whether there has been sudden power failure, whether the instrument has moved and other issues.


During maintenance, attention should be paid to the sequence of disassembly of medical equipment and do not force disassembly with brute force. Disassembled fastening screws, small pieces, etc., can not be conveniently placed, to be classified to avoid loss. After the completion of equipment maintenance, installation, and then in reverse order step by step to restore the original, no redundant accessories. The damaged parts should also be marked and restored to their original appearance after replacement, without any mistakes.


After the maintenance work is completed, clean the surface of the instrument, connect the power supply, to see if it can work normally. Calibrate the instrument to return to normal working state, and then hand it over to the user for trial to check whether the instrument is restored to the original working state, so as to avoid leaving hidden dangers. After cleaning the site, check whether there are missing tools, and fill in the maintenance log for future reference.


The protection engineer in maintenance should always pay attention to the protection work when maintaining the instrument, whether it is leakage or cross infection and other problems, should pay attention to the protection. Don't cause unnecessary injuries.


Third point: regular maintenance inspection, problems found as soon as possible, as soon as possible to solve.


Detailed preventive maintenance should include:


Appearance inspection: first of all, check whether the buttons, switches, joints and sockets of the instrument are loose and misplaced, whether the contact of plugs and sockets is oxidizing, rusting or poor contact, whether the power line is aging, whether the heat dissipation and exhaust air are normal, whether the connection of all kinds of grounding and pipe is good.


Cleaning and maintenance: it is to clean the electrical and mechanical parts of the surface and the internal parts of the instrument, including cleaning the filter screen and the relevant pipes, cleaning the relevant plugs and sockets of the instrument, to prevent bad contact, and lubricating the necessary mechanical parts.


Replacement of wearing parts: to have reached the service life and performance decline, substandard components or parts required to be replaced regularly as specified in the operation manual to timely replace, to prevent the possible expansion of the fault or cause the machine failure. In the case of insufficient battery charging, the relevant personnel should be urged to charge regularly, and all kinds of obvious and potential faults of the equipment should be eliminated.


Performance test calibration: test the voltage stability value of each DC power supply, the voltage value or waveform to be tested in the circuit, and make necessary calibration and adjustment according to the requirements of the manual, in order to ensure that the technical indicators of the instrument meet the standards, to ensure the quality of the instrument in medical diagnosis and treatment.


Safety check: 1. Check whether the frame is firm, whether the mechanical operation is normal, and whether the connecting parts are loose, fall off or rupture. 2. Check whether various leads, plugs and connectors are damaged, whether the grounding wire is firm, and whether the grounding resistance and leakage current are within the allowable limit.

Contact us

ComHuge (Dongguan) Medical Wire Harness Technology Co., Ltd

Hotline: +86-13929208661

Learn more

Feedback

© 2020-2021 ComHuge (Dongguan) Medical Wire Harness Technology Co., Ltd All Rights Reserved.   Powered by: ytclouds.net
主站蜘蛛池模板: 美女中出视频 | 国产ts人妖系列视频网站 | 九九精品99久久久香蕉 | 国产伦精品一区二区三区无广告 | 国产小视频免费在线观看 | 九一国产精品视频 | 精品久久久一二三区 | 国产亚洲欧美在线中文无广告 | 久久97久久97精品免视看清纯 | 国内精品久久久久 | 久久国产精品一区二区 | 九九视频免费精品视频免费 | 国产99欧美精品久久精品久久 | 国产在线精品一区二区 | 高清国产精品久久 | 国产高清国产专区国产精品 | 精品久久久久久 | 成人国产在线看不卡 | 国产欧美一区二区三区免费看 | 精品亚洲永久免费精品 | 免看一级a毛片一片成人不卡 | 久久这里只精品热免费99 | 久久国产精品免费看 | 成人午夜视频在线播放 | 狠狠操中文字幕 | 国产成人精品日本欧美动漫 | 国产成人精品免费视频 | 干美女在线视频 | 国产成人精品一区二区三区 | 高清在线一区 | 国产视频三级 | 国语高清精品一区二区三区 | 久久久久久久综合狠狠综合 | 成人国产永久福利看片 | 国产午夜精品久久久久九九 | 国内精品久久久久影院蜜芽 | 欧美a一 | 久久一区二区精品综合 | 精品久久网 | 国产精品一区不卡 | 国产男女猛烈 |