午夜欧美日韩-午夜欧美日韩在线视频播放-午夜欧美性视频在线播放-午夜欧美在线-欧美在线不卡-欧美在线不卡视频

Welcome to ComHuge (Dongguan) Medical Wire Harness Technology Co., Ltd website!

Product | Contact | 中文

Professional manufacturer of
medical wire harness

+86-13929208661

Hot search: High frequency electric knife wireNegative plate connecting wireBlood oxygen wire

News

Technical support Position: Home > News > Technical support

Matters needing attention for wiring harness maintenance of medical instruments and equipment

Date: 2021-03-30 Visited: 442

At present, the maintenance of medical equipment is a very complicated work, many medical institutions have equipment department, responsible for maintaining the safety and stability of equipment, but there are many problems that many equipment maintenance personnel do not understand or pay attention to. Here to everyone under the medical equipment wiring harness maintenance and maintenance.


The first point: meticulous daily maintenance, to ensure the normal operation of equipment is crucial.


Daily maintenance seems simple, but many times is not paid attention to, but also easy to ignore; But a lot of times big problems are compounded by small problems. To do with the clinical use of active cooperation, keep the surface of the instrument clean; Check whether the voltage and power supply are normal before use; During use, observe whether the function of the instrument is normal and fill in the use record. Develop good habits during routine maintenance to avoid damage.


Second point: equipment maintenance work, must be carefully handled, do not careless.


In case of equipment failure, information collection and preparation work should be done before maintenance. Including the model number, factory number, time of fault occurrence, abnormal sound when the fault occurs, whether there has been sudden power failure, whether the instrument has moved and other issues.


During maintenance, attention should be paid to the sequence of disassembly of medical equipment and do not force disassembly with brute force. Disassembled fastening screws, small pieces, etc., can not be conveniently placed, to be classified to avoid loss. After the completion of equipment maintenance, installation, and then in reverse order step by step to restore the original, no redundant accessories. The damaged parts should also be marked and restored to their original appearance after replacement, without any mistakes.


After the maintenance work is completed, clean the surface of the instrument, connect the power supply, to see if it can work normally. Calibrate the instrument to return to normal working state, and then hand it over to the user for trial to check whether the instrument is restored to the original working state, so as to avoid leaving hidden dangers. After cleaning the site, check whether there are missing tools, and fill in the maintenance log for future reference.


The protection engineer in maintenance should always pay attention to the protection work when maintaining the instrument, whether it is leakage or cross infection and other problems, should pay attention to the protection. Don't cause unnecessary injuries.


Third point: regular maintenance inspection, problems found as soon as possible, as soon as possible to solve.


Detailed preventive maintenance should include:


Appearance inspection: first of all, check whether the buttons, switches, joints and sockets of the instrument are loose and misplaced, whether the contact of plugs and sockets is oxidizing, rusting or poor contact, whether the power line is aging, whether the heat dissipation and exhaust air are normal, whether the connection of all kinds of grounding and pipe is good.


Cleaning and maintenance: it is to clean the electrical and mechanical parts of the surface and the internal parts of the instrument, including cleaning the filter screen and the relevant pipes, cleaning the relevant plugs and sockets of the instrument, to prevent bad contact, and lubricating the necessary mechanical parts.


Replacement of wearing parts: to have reached the service life and performance decline, substandard components or parts required to be replaced regularly as specified in the operation manual to timely replace, to prevent the possible expansion of the fault or cause the machine failure. In the case of insufficient battery charging, the relevant personnel should be urged to charge regularly, and all kinds of obvious and potential faults of the equipment should be eliminated.


Performance test calibration: test the voltage stability value of each DC power supply, the voltage value or waveform to be tested in the circuit, and make necessary calibration and adjustment according to the requirements of the manual, in order to ensure that the technical indicators of the instrument meet the standards, to ensure the quality of the instrument in medical diagnosis and treatment.


Safety check: 1. Check whether the frame is firm, whether the mechanical operation is normal, and whether the connecting parts are loose, fall off or rupture. 2. Check whether various leads, plugs and connectors are damaged, whether the grounding wire is firm, and whether the grounding resistance and leakage current are within the allowable limit.

Contact us

ComHuge (Dongguan) Medical Wire Harness Technology Co., Ltd

Hotline: +86-13929208661

Learn more

Feedback

© 2020-2021 ComHuge (Dongguan) Medical Wire Harness Technology Co., Ltd All Rights Reserved.   Powered by: ytclouds.net
主站蜘蛛池模板: 国产精品福利在线观看免费不卡| 国产中的精品一区的| 国产精品视频全国免费观看| 国产三级小说| 国产亚洲精品91| 免费污的网站| 免费一级毛片在线播放视频| 九九热综合| 国产大陆精品另类xxxx| 东京干手机福利视频| 国产特级毛片aaaaaa| 免费视频xxx| 国产国语一级毛片在线视频| 国产精品区在线12p| 国产66| 国产精品久久久久毛片| 国产福利影院在线观看| 久久3| 国产一区二区视频免费| 国产高清av在线播放| 国内激情| 精品国产一区二区麻豆| 国产特级淫片免费看| 久久综合九色综合网站| 国产九九在线| 黄色在线| 久久精品国产免费中文| 国产精品综合| 看真人一级毛片| 久久久久久尹人网香蕉| 国产一二三区在线观看| 毛片18| 久久怡红院国产精品| 九九五月天| 干b视频在线观看| 黄色激情视频网站| 国产做a爰片久久毛片| 久久中文字幕一区二区| 国产精品视频免费观看| 成人永久免费| 国产精品亚洲片在线观看不卡|